• Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock
  • Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock
  • Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock
  • Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock
  • Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock
  • Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock

Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock

Material: Iron
Usage: for Air Conditioner
Flow Direction: Centrifugal
Pressure: Low Pressure
Certification: RoHS, ISO, CE
OEM: Yes
Samples:
US$ 150/Set 1 Set(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Anhui, China
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (22)
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • FAQ
Overview

Basic Info.

Model NO.
800/900/1000/1100/1220/1380/1530
ODM
Yes
Weight
58-85kg
Blade
Stainless Steel
Transport Package
Carton
Specification
13800*13800*400mm
Trademark
HP
Origin
Bengbu
HS Code
8414599000
Production Capacity
500sets

Product Description

 

Product Description

 

Ventilation principle of drop hammer fan

 

The main function of the hammer fan is to cool and exhaust, so do you understand its ventilation principle?
The fan exhausts the air outward, which makes the indoor air pressure drop and the indoor air become thinner, forming a negative pressure area. The air flows into the room due to the compensation of the pressure difference. In the practical application of industrial plant, the fan is installed on one side of the plant, the air inlet is on the other side of the plant, and the air is convective from the air inlet to the fan. In this process, the doors and windows near th fan remain closed, forcing air into the workshop from the door and window on the air inlet side. The air in line and orderly flows into the workshop from the air inlet, flows through the workshop, and is discharged from the workshop by the fan.

 

Detailed Photos



Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock

Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock
Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock
Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock
Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock

 

Product Parameters

 

Modle                           specification Diameter blades(mm) Blades rotational speed Motor rotational speed rpm Air flow     (m³/h) (Pa)                total pressure Noise decibels Import power(w) Rated voltage(v) Height(mm) Width(mm) Thickness(mm)
JMD-800(29'') 710 660 1400 22000 60 60 370 380 800 800 400
JMD-900(30'') 750 630 1400 28000 65 65 550 380 900 900 400
JMD-1000(36'') 900 610 1400 30000 70 70 750 380 1000 1000 400
JMD-1100(40'') 1000 600 1400 32500 70 70 750 380 1100 1100 400
JMD-1220(44'') 1100 460 1400 38000 73 70 1100 380 1220 1220 400
JMD-1380(50'') 1250 439 1400 44000 56 75 1100 380 1380 1380 400
JMD-1530(56'') 1400 325 1400 55800 60 70 1500 380 1530 1530 400


Ventilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/LivestockVentilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/LivestockVentilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/LivestockVentilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/LivestockVentilation Hammer Push-Pull/Centrifugal/Shutter Axial Cone Exhaust Fan Wall Fan for Poultry Farm /Greenhouse Exhaust/Workshop/Livestock

 

FAQ


1.Are you trading company or manufacturer ?
   We are manufacturer and produce by ourself.

2.When can i get the quotation?
   You will be able to obtain it within 24 hours once we get your inquiry.

3.How about  your delivery time ?
   We will finish the order within 15 days for 40ft container,if more we need negotiate with you.

4.Do you provide samples? Is it free ?
   Yes, we could offer the free samples for evaluation but do not pay the cost of freight.

5.Can you accept OEM or ODM?
   Yes, of course.
                                            

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
100
Year of Establishment
2017-08-18